The energy management system for critical industrial sites
DAT'Power consolidates multi-utility data of an industrial site (electricity, steam, gas, compressed air, water, cooling) to manage daily energy performance and prepare for ISO 50001, French Decree Tertiary, and BACS compliance audits.

Download the DAT'Power technical documentation
Without an energy platform, your facility operates without visibility across three areas
Do you have a project you would like to discuss with our technical team?

Four use cases, one platform
Measure what matters.
Understand what is consuming, where, when, and why at both the utility and equipment levels.
Without over-instrumenting: the metering plan is scaled for a rapid return on investment, not for stacking up sensors.
Detecting before the drift occurs
Identify anomalies at the moment they occur—such as leaks, atypical behavior, or deviations from reference operations—and quantify the excess cost before it becomes persistent.
Adjusting setpoints
Remotely adjust operating parameters (power, schedules, thresholds) according to production requirements or operating conditions.
Smooth peaks and eliminate consumption without active use, without degrading operational performance.
Demonstrating compliance
Generate the data and indicators required for ISO 50001, OPERAT, BACS, and IPMVP audits.
Continuous monitoring rather than annual reconstruction.
6 sources, one single platform
DAT'Power covers all energy utilities of an industrial site. Deployment is prioritized based on site-specific challenges rather than systematic instrumentation of all utilities, using a metering plan sized for a rapid ROI and a clear expansion roadmap.
Water
Monitoring of city water, effluents, tanks, and condensates. Leak detection and consumption analysis to reduce usage and manage a water sobriety plan.
Steam
Analysis of boilers, feed tanks, and steam traps. Monitoring of condensate return and optimization of water makeup to improve steam network efficiency.
Gas
Monitoring of air heaters, ovens, and boilers. Optimization of heating profiles based on equipment characteristics, environmental conditions, and production requirements.
Industrial refrigeration
Monitoring of chillers and cold rooms. Performance analysis via Delta T and control system adjustment to operate facilities at their optimal efficiency.
Compressed air
Analysis of compressors, dryers, and air networks. Leak detection, air quality monitoring, and pressure adjustment to improve energy efficiency.
ISO 50001
Energy management system.
The core reference framework. DAT'Power covers the measurement of significant energy uses (UES), the establishment of energy performance indicators (IPE), the monitoring of baseline consumption, and the traceability of improvement actions. Certification is prepared and maintained without additional effort at the deadline.


Regulatory energy audit
DDADUE
Periodic obligation for large enterprises not certified under ISO 50001.
Continuous data consolidation reduces audit time and facilitates convergence toward an ISO 50001 approach if envisioned.
Tertiary Decree and BACS
OPERAT & BACS
For tertiary buildings with a surface area exceeding 1,000 m² located on industrial, administrative, R&D, or catering sites.
DAT'Power measures energy consumption, generates OPERAT declarations, and supports BACS compliance for HVAC systems.


Measurement and verification of savings
IPMVP
Quantifying savings after an energy efficiency project requires a robust methodology. DAT'Power applies IPMVP principles (options A to D depending on the scope) to ensure savings are contractually binding and verifiable for the group, financiers, or third-party auditors.
Read the Ninkasi case study
A phased deployment, aligned with your industrial realities and operational priorities
The deployment of DAT’Power is based on a structured, phased methodology tailored to your organization, from the initial analysis of your facilities to the continuous optimization of your energy performance.